Equipment Calibration
Maintain confidence in your measurement and control instruments with calibration against traceable standards.
Onsite and Laboratory Calibration
An instrument drifts out of specification long before anything about it looks wrong. It keeps reading, it keeps displaying a plausible number, and the process is quietly adjusted around it. Calibration places a known reference against the instrument and establishes how far the two disagree, which is the only way to know whether a measurement can be relied upon.
Calibration is performed onsite in the installed position wherever access allows, because that is the condition the instrument actually works in, and in the workshop where the installed position prevents a proper reference being applied. The instrument is first checked for physical damage and for evidence that its case or seals have been opened, and the reference standard and the instrument are allowed to reach thermal equilibrium before readings are taken at the calibration point, normally between 10 and 90 percent of span.
The distinction between as-found and as-left matters commercially as well as technically. An as-found result shows what the instrument was actually reading in service, which is what a quality system is judged on. An as-left result shows it has been brought back within tolerance. We report both, and we will not adjust an instrument unless you ask us to.
Instruments calibrated include:
- Pressure: gauges, differential pressure gauges, transmitters, recorders and switches
- Temperature: thermocouples, resistance temperature detectors, transmitters, indicators and infrared thermometers
- Electrical: digital multimeters, clamp meters, insulation resistance testers, micro-ohmmeters, earth testers and power quality analysers
- Process: flow, level, density and mass flow instrumentation
- Dimensional and mechanical: micrometers, verniers, gauges, torque tools and angle measuring instruments
- Signal path: transducers, transmitters, recorders, alarms and analysers
Each instrument receives a certificate identifying it by asset tag, with its as-found and as-left readings against the reference value, the calculated error for each point and whether it is within the stated tolerance, the adjustment carried out where authorised, the reference standards used with their own calibration status, and the accredited body, certificate number and scope of accreditation. Any instrument found out of tolerance is reported as such, together with what that means for the process it was measuring.
Other services
Explore the rest of
what we do.
Electric Motor Analysis
Assess the electrical and mechanical condition of motors so developing faults are found before they stop production.
Thermographic Survey
Locate abnormal heat patterns on electrical and mechanical assets before that heat becomes a failure.
Airborne and Structure Borne Ultrasound
Detect leaks, arcing and failing bearings using high-frequency sound, at ranges that ordinary thermography cannot reach.
Laser Alignment
Correct shaft misalignment with laser tooling, extending bearing and seal life and reducing energy use.
Partial Discharge Analysis
Evaluate insulation condition in critical high-voltage equipment so deterioration is measured before it fails.
Onsite Dynamic Balancing
Correct unbalance in rotating equipment while it runs, without removing the rotor from the machine.
Vibration Analysis
Identify rotating machinery faults and track how equipment condition is changing, route by route and trend by trend.
Equipment Rental
Access specialist diagnostic and test equipment for planned work, without the capital cost or the lead time.